clear mac algorithm
14-24 Logging and Network Management
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowstheoutputofthiscommand.
C2(su)->show mac algorithm
Mac hashing algorithm is mac-crc16-upperbits.
clear mac algorithm
UsethiscommandtoreturntheMAChashingalgorithmtothedefaultvalueofmaccrc16
upperbits.
Syntax
clear mac algorithm
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleresetstheMAChashingalgorithmtothedefaultvalue.
C2(su)->clear mac algorithm
set mac multicast
UsethiscommandtodefineonwhatportswithinaVLANamulticastaddresscanbedynamically
learnedon,oronwhatportsaframewiththespecif iedMACaddresscanbeflooded.Also,use
thiscommandtoappendportstoorclearportsfromtheegressportslist.
Syntax
set mac multicast mac-address vlan-id [port-string] [{append | clear} port-string]

Table of Contents

Other manuals for Enterasys SecureStack C2 C2G170-24

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys SecureStack C2 C2G170-24 and is the answer not in the manual?

Enterasys SecureStack C2 C2G170-24 Specifications

General IconGeneral
BrandEnterasys
ModelSecureStack C2 C2G170-24
CategorySwitch
LanguageEnglish

Related product manuals