set vlan name
10-6 802.1Q VLAN Configuration
set vlan name
UsethiscommandtosetorchangetheASCIInameforaneworexistingVLAN.
Syntax
set vlan name vlan-list vlan-name
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthenameforVLAN7togreen:
C2(su)->set vlan name 7 green
clear vlan
UsethiscommandtoremoveastaticVLANfromthelistofVLANsrecognizedbythedevice .
Syntax
clear vlan vlan-list
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoremoveastaticVLAN9fromthedevice’sVLANlist:
C2(su)->clear vlan 9
vlanlist SpecifiestheVLANIDoftheVLAN(s)tobenamed.
vlanname SpecifiesthestringusedasthenameoftheVLAN(1to32characters).
vlanlist SpecifiestheVLANIDoftheVLAN(s)toberemoved.