show switch switchtype
SecureStack C2 Configuration Guide 2-7
Examples
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±informationî ±aboutî ±allî ±switchî ±unitsî ±inî ±theî ±stack:
C2(rw)->show switch
Management Preconfig Plugged-in Switch Code
Switch Status Model ID Model ID Status Version
------ ------------ ------------- ------------- --------------------- --------
1 Mgmt Switch C2G124-24 C2G124-24 OK 05.02.xx.xxxx
2 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
3 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
4 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
5 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
6 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
7 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
8 Stack Member C2G124-24 C2G124-24 OK 05.02.xx.xxxx
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±informationî ±aboutî ±switchî ±unitî ±1î ±inî ±theî ±stack:
C2(ro)->show switch 1
Switch 1
Management Status Management Switch
Hardware Management Preference Unassigned
Admin Management Preference Unassigned
Switch Type C2G124-24
Preconfigured Model Identifier C2G124-24
Plugged-in Model Identifier C2G124-24
Switch Status OK
Switch Description Enterasys Networks, Inc. C2 -- Model
C2G124-24
Detected Code Version 05.02.xx.xxxx
Detected Code in Flash 03.01.20
Detected Code in Back Image 02.01.37
Up Time 0 days 6 hrs 37 mins 54 secs
Thisî ±exampleî ±showsî ±howî ±toî ±displayî ±statusî ±informationî ±forî ±switchî ±unitî ±1î ±inî ±theî ±stack:
C2(ro)->show switch status 1
Switch 1
Switch Status Full
Admin State
Power State
Inserted Switch:
Model Identifier C2G124-24
Description Enterasys Networks, Inc. C2 -- Model
C2G124-24
Configured Switch:
Model Identifier C2G124-24
Description Enterasys Networks, Inc. C2 -- Model
C2G124-24
show switch switchtype
Useî ±thisî ±commandî ±toî ±displayî ±informationî ±aboutî ±supportedî ±switchî ±typesî ±inî ±theî ±stack.
Syntax
show switch switchtype [switchindex]