Step 22
Did the Main blade had a USB ash drive that was removed in Step 1?
If YES:
Connue with next step.
If NO:
Proceed to Step 26.
Step 23
Insert USB ash drive in the replacement Main blade.
Step 24
Turn the power on at the source and wait for the blade to inialize.
Warning: Aer the blade is powered up, power down within 15 minutes causes database corrupon,
which leads to blade start-up failure and requires a return to factory for reprogramming.
Step 25
Verify that previous OSL and provisioning are restored to Main blade.
Step Result:
Procedure is complete.
Step 26
Is a database backup available for the blade being replaced?
If YES:
Proceed to Restore Conguraon Database and connue with next step.
If NO:
Proceed to Equipment Installaon and connue with next step.
Step 27
Turn the power on at the source and wait for the blade to inialize.
Step 28
Provision the tributary blade equipment.
Command:
> request set-shelfmode shelfid <x> shelfrole TRIB
Step Result:
Procedure is complete.
This task is complete.
System Maintenance
Equipment Replacement
411
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu 1FINITY L100 and is the answer not in the manual?

Fujitsu 1FINITY L100 Specifications

General IconGeneral
BrandFujitsu
Model1FINITY L100
CategoryServer
LanguageEnglish

Related product manuals