Par. No. # Parameter description Default value 4-set-up Change during opera-
tion
Conver-
sion index
Type
B-0#
B-00 DC Hold Current 50 % All set-ups TRUE 0 Uint8
B-01 DC Brake Current 50 % All set-ups TRUE 0 Uint16
B-02 DC Braking Time 10.0 s All set-ups TRUE -1 Uint16
B-03 DC Brake Cut In Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
B-04 DC Brake Cut In Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
B-1#
B-10 Brake Function [0] Off All set-ups TRUE - Uint8
B-11 Brake Resistor (ohm) ExpressionLimit All set-ups TRUE 0 Uint16
B-12 Brake Power Limit (kW) ExpressionLimit All set-ups TRUE 0 Uint32
B-13 Braking Thermal Overload [0] Off All set-ups TRUE - Uint8
B-15 Brake Check [0] Off All set-ups TRUE - Uint8
B-16 AC brake Max. Current 100.0 % All set-ups TRUE -1 Uint32
B-17 Over-voltage Control [2] Enabled All set-ups TRUE - Uint8
7.2.24 B-## Braking Functions
AF-600 FP High Power Operating Instructions
148
7

Table of Contents