Communication Timing 6-45
6.5.2 Response Time
(1) Time interval (T1) between external device communication and IJ printer
response
External device
IJ printer
ENQ
STX
ETX
ACK
T0
T1
No. Transmission type Conditions T1 Maximum time (ms) Remarks
1 Print description
The print message
transfer ACK condition
is t=fixed.
10 *1
The print message
transfer ACK condition
is t=async.
N+25
(N: Number of
communication items)
*1 *2
2 Print data recall - 5
3
Print conditions
Print specifications 10
4 Print format 20
5 Overall column setup 20
6
User pattern
character
-
M+10
(M: Number of
communication characters)
Baud rate (bps) T0 Maximum time (ms)
150 to 1200 5
2400 to 38400 1
*1 For "t=fixed" and "t=async.", see Section 6.2.1, "Setting Communication Environment ".
*2 When there is a data matrix setting, the time is as follows:
Time T1 when there is a data matrix setting
Character size T1 Maximum time (ms)
5x8 8x N+20
12x16, 18x24 15x N+40
ACK

Table of Contents