Figure 6-6 Replacing the Airflow Guide
4. Ensure that the fans are seated correctly in their connectors by gently pressing down on
each fan in the fan carrier.
5. Replace the top cover. See “Replacing the Top Cover (page 144).
6. Replace the server back into the rack. See “Inserting the Server into the Rack” (page 143).
Removing and Replacing a Hot-Swappable Server Fan
When removing a hot-swappable server fan from the server, there are different procedures
depending on if you have a Data Center rx2660 server or an rx2660 Office Friendly server.
Data Center rx2660 Server
Twelve fans cool the Data Center server. The fans are all redundant, hot-swappable, and
interchangeable. Fans 1 through 8 are located in a removable fan carrier directly behind the front
bezel. Fan units 9 through 12 are located in a removable I/O fan carrier between the SAS backplane
and the I/O card cage. The server is set up into three cooling zones. Fans 1 through 4 cool Zone
1. Fans 5 through 8 cool Zone 2. Fans 9 through 12 cool Zone 3. Each zone can have one fan failure
and still run, with the other fans in the zone speeding up until the failed fan is replaced. Replace
the fans using the procedures in this section whether the server is powered on or off.
Figure 6-7 (page 149) shows the fan and cooling zone locations.
148 Removing and Replacing Server Components

Table of Contents

Other manuals for HP Integrity rx2660

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2660 and is the answer not in the manual?

HP Integrity rx2660 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx2660
CategoryServer
LanguageEnglish

Related product manuals