EasyManuals Logo
Home>HP>Server>Integrity rx2660

HP Integrity rx2660 User Manual

HP Integrity rx2660
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #173 background imageLoading...
Page #173 background image
7. Reconnect the power cables and power on the server. See “Powering On and Powering Off
the Server (page 78).
NOTE: When replacing the fan/display board you are prompted to copy the primary UUID
to the secondary location (PRI to SEC). Reply y.
Removing and Replacing System Memory
System memory modules, or DIMMs, are located on the system board.
WARNING! Ensure that the system is powered off and all power sources are disconnected
from the server prior to performing this procedure.
Voltages are present at various locations in the server whenever an ac power source is connected.
This voltage is present even when the main power switch is in the off position.
Failure to observe this warning can result in personal injury or damage to equipment.
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions can result in damage to the server.
Removing System Memory
To remove system memory, follow these steps:
1. Power off the server and disconnect the power cables. See “Powering On and Powering Off
the Server (page 78).
2. If rack mounted, slide the server out from the rack until it stops. See “Extending the Server
from the Rack” (page 142).
3. Remove the top cover from the server. See “Removing the Top Cover (page 143).
4. Remove the airflow guide. See “Removing the Airflow Guide” (page 145).
5. Release the DIMM from the slot.
a. Identify on the system board which DIMM you want to remove. See Figure 6-27 for the
slot IDs.
b. Push the appropriate extraction levers (found on either side of the DIMM slot) outward
to the open position.
6. Remove the DIMM from the slot.
Figure 6-27 shows the memory slots on the system board.
Figure 6-27 Memory Location and Slot IDs
Removing and Replacing System Memory 173

Table of Contents

Other manuals for HP Integrity rx2660

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx2660 and is the answer not in the manual?

HP Integrity rx2660 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx2660
CategoryServer
LanguageEnglish

Related product manuals