Procedure (on the BIOS)
Step 1 Restart the server, and enter the BIOS.
For details, see 9.6 Accessing the BIOS.
Step 2 Choose Advanced > IPMI iBMC Conguration and press Enter.
The IPMI iBMC Conguration screen is displayed.
Step 3 Select iBMC Conguration and press Enter.
The iBMC Conguration screen is displayed, showing the iBMC IP address.
Step 4 Select IPv4 IP Address and press Enter.
The IPv4 IP Address dialog box is displayed.
Step 5 Change the IPv4 address of the iBMC management network port.
Step 6 Press F10.
Save the settings and exit.
----End
7.4.6
Conguring RAID
The 2288X V5 supports multiple types of RAID controller cards.
● Use Intelligent Computing Compatibility Checker to obtain information
about the compatible RAID controller cards.
● The
conguration method varies depending on the RAID controller card
model. For details, see Huawei V5 Server RAID Controller Card User Guide.
7.4.7
Conguring the BIOS
Scenarios
This section describes how to congure the BIOS of the server.
To
congure the BIOS, perform the following operations:
● Set the system boot sequence
● Set PXE for a NIC
● Set the BIOS password
● Select a language
For details about other
congurations, see Huawei Server Purley Platform BIOS
Parameter Reference.
FusionServer Pro 2288X V5 Server
User Guide 7 Installation and Conguration
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 105