Table 2-9 Description of NVMe drive indicators (VMD enabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
O O The NVMe drive cannot be detected.
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written
to the NVMe SSD.
O Blinking at 2 Hz The NVMe drive is being located.
O Blinking at 8 Hz The data on the secondary NVMe
drive is being rebuilt.
Steady on/O Steady on The NVMe drive is faulty.
● If the VMD function is disabled, NVMe drives support only orderly hot swap.
Table 2-10 NVMe drive indicators (VMD disabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
O O The NVMe drive cannot be detected.
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written
to the NVMe drive.
O Blinking at 2 Hz The NVMe drive is being located or
hot-swapped.
O Blinking at 0.5
Hz
The hot removal process is
complete, and the NVMe drive is
removable.
Steady on/O Steady on The NVMe drive is faulty.
2.5.4 RAID Controller Card
The RAID controller card supports RAID conguration, RAID level migration, and
drive roaming.
● PCIe plug-in RAID controller cards and screw-in RAID controller cards are
supported.
● Contact your local Huawei sales representative or use the Intelligent
Computing Compatibility Checker to determine the components to be used.
● For details about the RAID controller card, see Huawei V5 Server RAID
Controller Card User Guide.
FusionServer Pro 2288X V5 Server
User Guide 2 Hardware Description
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 31