Indicator Description
UID indicator The UID indicator helps identify and locate a device.
● O: The device is not being located.
● Blinking blue: The device has been located and is
dierentiated from other devices that have also
been located.
● Steady blue: The device is being located.
NOTE
You can turn on or o the UID indicator by pressing the UID
button or remotely running a command on the iBMC CLI.
PSU indicator ● O: No power is supplied.
● Blinking green at 1 Hz:
– The input is normal, and the server is standby.
– The input is overvoltage or undervoltage.
– The PSU is in deep hibernation mode.
● Blinking green at 4 Hz: The
rmware is being
upgraded online.
● Steady green: The power input and output are
normal.
● Steady orange: The input is normal, but no power
output is supplied.
NOTE
The possible causes of no power output are as follows:
● Power supply overtemperature protection
● Power output overcurrent or short-circuit
● Output overvoltage
● Short-circuit protection
● Device failure (excluding failure of all devices)
2.2.3 Ports
Port Positions
Figure 2-15 Rear view
FusionServer Pro 2288X V5 Server
User Guide 2 Hardware Description
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 14