● Memory thermal throttling
● Memory address parity protection
● Memory demand/patrol scrubbing
● Device tagging
● Data scrambling
● Adaptive double device data correction (ADDDC)
● ADDDC+1
2.5 Storage
2.5.1 Drive Congurations
Table 2-7 Drive congurations
Conguration Maximum Front
Drives
Maximum Rear
Drives
Drive
Management
Mode
8 x 2.5" drive
pass-through
conguration 1
● 8 x 2.5"
– Slots 0 to 7
support only
SATA drives.
● I/O module 3:
4 x 2.5"
– Slots 44 to
47 support
only NVMe
drives.
PCH
8 x 2.5" drive
pass-through
conguration 2
● 8 x 2.5"
– Slots 0 to 7
support only
SAS/SATA
drives.
● I/O module 3:
4 x 2.5"
– Slots 44 to
47 support
only NVMe
drives.
1 x screw-in RAID
controller card
8 x 2.5" drive
pass-through
conguration 3
● 8 x 2.5"
– Slots 0 to 7
support only
SAS/SATA
drives.
● I/O module 3:
4 x 2.5"
– Slots 44 to
47 support
only NVMe
drives.
1 x PCIe RAID
controller card
FusionServer Pro 2288X V5 Server
User Guide 2 Hardware Description
Issue 04 (2020-06-05) Copyright © Huawei Technologies Co., Ltd. 24