CE/CCC configurations (3-phase)
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 480 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 70 A / 68 A 58 A 29 A
Input current during arc stretch 98 A 98 A 50 A
Fuse (time-delay) 100 A 100 A 50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 400 V 480 V 600 V
Input current at rated output
(85 A × 143 VDC = 12.2 kW)
42 A / 40 A 35 A 21 A 18 A 17 A
Input current during arc stretch 60 A 60 A 38 A 31 A 30 A
Fuse (time-delay) 60 A 60 A 40 A 30 A 30 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 380 V 400 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 20.5 A 19.5 A
Input current during arc stretch 38 A 38 A
Fuse (time-delay) 40 A 40 A
* All models have a voltage tolerance of +10% / -15%.

Table of Contents

Other manuals for Hypertherm SYNC Powermax 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 65 and is the answer not in the manual?

Hypertherm SYNC Powermax 65 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 65
CategoryWelding System
LanguageEnglish

Related product manuals