6
MENU SCREEN
6-14
OP Vibration
Selects whether or not to vibrate the transceiver when
it is turned ON�
L To use this function, the Vibration function must be
turned ON, in advance�
OFF: Turns OFF the vibration�
Pattern 01: The transceiver vibrates for 5
seconds�
Pattern 02: The transceiver vibrates for 1
second three times�
Pattern 03: The transceiver vibrates for 0�5
seconds ve times.
Pattern 04: The transceiver vibrates for 0�3
seconds eight times�
Pattern 05 to 16: The transceiver vibrates, according
to the customized pattern�
NOTE: You can customize the Vibration pattern,
Vibration Repeat, and Interval time using the
programming software�
Vibration
Turns the Vibration function ON or OFF
L To vibrate the transceiver, set each Vibration
setting to ON using the programming software�
Depending on the Vibration setting, the transceiver
may vibrate:
When a call that includes a matching 2-Tone code is
received�
When a call that includes a matching 5-Tone code is
received�
When a Call Alert is received�
When a Message is received�
When a Status call that includes a matching status
number is received�
When a DTMF code is received�
When a user pushes a key
While in the Low Battery 1 state�
While in the Low Battery 2 state�
While in the Surveillance mode�
Key Vibration
Selects whether or not to vibrate the transceiver when
a user pushes a key
L To use this function, the Vibration function must rst
be turned ON�
Vibration Sensor
Man Dwn Ang
Sets the Emergency mode detection angle for the
Man Down function� If the transceiver leans past the
set angle for the ON Timer time period, the transceiver
enters the Emergency mode, and then a countdown
starts�
Options: 45, 60, or 75 degrees
Motion Sense
Sets the acceleration sensor sensitivity to detect
whether the user is moving or not, for the Motion
Detection function� This setting is for the Motion
Detection function, and it determines the acceleration
threshold level to activate the Motion Detection Timer
Range: 1 (high sensitivity) ~ 10 (low sensitivity)�
L If you set a lower level, the transceiver will enter the
Emergency mode sooner
Stat Sense
Sets the acceleration sensor sensitivity to detect if the
user is stationary or not for the Stationary Detection
function� This setting is used for the Stationary
Detection function, and it determines the acceleration
threshold level to activate the Stationary Detection’s
ON Timer (Sec)�
Range: 1 (high sensitivity) ~ 10 (low sensitivity)�
L If you set at a higher level, the transceiver will enter the
Emergency mode sooner
Desk Work
Key Operation
Walking (slow)
Walking (fast)
Running
Sensitivity Level
9
10
1
3
5
6
7
8
4
2
For Stationary
Sensitivity For Motion Sensitivity
• Sensitivity example

Table of Contents

Other manuals for Icom IC-F52D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-F52D and is the answer not in the manual?

Icom IC-F52D Specifications

General IconGeneral
BrandIcom
ModelIC-F52D
CategoryTransceiver
LanguageEnglish

Related product manuals