Platform Management Functional Overview Intel® Server Board S2600CO Family TPS
58 Revision 1.0
Intel order number G42278-002
FSB2 refers to the FRB algorithm that detects system failures during POST. The BIOS uses the
BMC watchdog timer to back up its operation during POST. The BIOS configures the watchdog
timer to indicate that the BIOS is using the timer for the FRB2 phase of the boot operation. After
the BIOS has identified and saved the BSP information, it sets the FRB2 timer use bit and loads
the watchdog timer with the new timeout internal.
If the watchdog timer expires while the watchdog use bit is set to FRB2, the BMC (if so
configured) logs a watchdog expiration event showing the FRB2 timeout in the event data bytes.
The BMC then hard resets the system, assuming the BIOS-selected reset as the watchdog
timeout action.
The BIOS is responsible for disabling the FRB2 timeout before initiating the option ROM scan
and before displaying a request for a boot password. If the processor fails and causes an FRB2
timeout, the BMC resets the system.
The BIOS gets the watchdog expiration status from the BMC. If the status shows an expired
FRB2 timer, the BIOS enters the failure in the system event log (SEL). In the OEM bytes entry
in the SEL, the last POST code generated during the previous boot attempt is written. FRB2
failure is not reflected in the processor status sensor value.
The FRB2 failure does not affect the front panel LEDs.
6.6 Sensor Monitoring
The BMC monitors system hardware and reports system health. Some of the sensors includes
those for monitoring.
Component, board, and platform temperatures
Board and platform voltages
System fan presence and tach
Chassis intrusion
Front Panel NMI
Front Panel Power and System Reset Buttons
SMI timeout
Processor errors
The information gathered from physical sensors is translated into IPMI sensors as part of the
“IPMI Sensor Model”. The BMC also reports various system state changes by maintaining
virtual sensors that are not specifically tied to physical hardware.
See Appendix C Integrated BMC Sensor Tables for additional sensor information.
6.7 Field Replaceable Unit (FRU) Inventory Device
The BMC implements the interface for logical FRU inventory devices as specified in the
Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides
commands used for accessing and managing the FRU inventory information. These commands
can be delivered through all interfaces.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600CO Family and is the answer not in the manual?

Intel S2600CO Family Specifications

General IconGeneral
BrandIntel
ModelS2600CO Family
CategoryServer Board
LanguageEnglish

Related product manuals