Series 2600B
System SourceMeter® Instrument Reference Manual Section 5: Introducti
on to TSP operation
2600BS-901-01 Rev. B / May 2013 5-5
Digital I/O
The Models 2604B, 2614B, and 2634B do not have digital input/output lines. The commands to
control the digital input/output lines are not available for these models.
The digital I/O port of the instrument can control external circuitry (such as a component handler for
binning operations).
The I/O port has 14 lines. Each line can be at TTL logic state 1 (high) or 0 (low). See the pinout
diagram in Digital I/O port (on page 3-83
) for additional information.
There are commands to read and write to each individual bit, and commands to read and write to the
entire port.
digio.readbit() (on page 7-49)
digio.readport() (on page 7-50)
digio.trigger[N].assert() (on page 7-51)
digio.trigger[N].clear() (on page 7-51)
digio.trigger[N].EVENT_ID (on page 7-52)
digio.trigger[N].mode (on page 7-52)
digio.trigger[N].overrun (on page 7-54)
digio.trigger[N].pulsewidth (on page 7-54)
digio.trigger[N].release() (on page 7-55)
digio.trigger[N].reset() (on page 7-55)
digio.trigger[N].stimulus (on page 7-56)
digio.trigger[N].wait() (on page 7-58)
digio.writebit() (on page 7-58)
digio.writeport() (on page 7-59)
digio.writeprotect (on page 7-60)
Display
display.clear() (on page 7-60)
display.getannunciators() (on page 7-61)
display.getcursor() (on page 7-62)
display.getlastkey() (on page 7-63)
display.gettext() (on page 7-64)
display.inputvalue() (on page 7-65)
display.loadmenu.add() (on page 7-67)
display.loadmenu.catalog() (on page 7-68)
display.loadmenu.delete() (on page 7-69)
display.locallockout (on page 7-69)
display.menu() (on page 7-70)
display.numpad (on page 7-71)
display.prompt() (on page 7-71)
display.screen (on page 7-73)
display.sendkey() (on page 7-73)
display.setcursor() (on page 7-75)
display.settext() (on page 7-76)
display.smuX.limit.func (on page 7-77)
display.smuX.measure.func (on page 7-78)
display.smuX.digits (on page 7-77)
display.trigger.clear() (on page 7-79)
display.trigger.EVENT_ID (on page 7-79)
display.trigger.overrun (on page 7-79)
display.trigger.wait() (on page 7-80)
display.waitkey() (on page 7-81)

Table of Contents

Other manuals for Keithley 2611B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2611B and is the answer not in the manual?

Keithley 2611B Specifications

General IconGeneral
BrandKeithley
Model2611B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals