95PERIODIC SERVICE
EVERY 50 HOURS SERVICE
BChecking the battery condition
To avoid the possibility of a battery explosion:
For refillable type battery, follow the instructions
below.
A Do not use or charge the refillable type battery
if the fluid level is below the LOWER (lower limit
level) mark. Otherwise, the battery component
parts may prematurely deteriorate, which may
shorten the battery's service life or cause an
explosion. Check the fluid level regularly and
add distilled water as required so that the fluid
level is between the UPPER and LOWER levels.
To avoid personal injury or death:
A Never remove the vent caps while the engine is
running.
A Keep electrolyte away from eyes, hands and
clothes. If you are spattered with it, wash it
away completely with water immediately and
get medical attention.
A Wear eye protection and rubber gloves when
working around the battery.
A Before inspection or dismounting the battery,
be sure to turn off the engine and turn the
starter switch to the "STOP" position.
A When removing the battery, always disconnect
the negative ground cable first. When installing
a battery, always connect the ground cable
last. This prevents a possible explosion caused
by sparks.
A Always wear eye protection when working with
the battery.
Mishandling the battery shortens the service life and adds
to maintenance costs.
The original battery is maintenance free, but needs some
servicing.
If the battery is weak, the engine will be difficult to start
and the lights will be dim. It is important to check the
battery periodically.
The battery is in the left side cover. Refer to page 85 for
how to open it.
C Battery Charging
To avoid personal injury or death:
A When the battery is being activated, hydrogen
and oxygen gases in the battery are extremely
explosive. Keep open sparks and flames away
from the battery at all times, especially when
charging the battery.
A When charging the battery, ensure the vent
caps are securely in place. (if equipped)
A When disconnecting the cable from the battery,
start with the negative terminal first.
When connecting the cable to the battery, start
with the positive terminal first.
A Never check battery charge by placing a metal
object across the posts.
Use a voltmeter or hydrometer.
(A) "Upper level"
(B) "Lower level"
The factory-installed battery is of non-refillable type.
If the indicator turns white, do not quick charge the
battery but replace it with new one.
(1) Battery
(2) Left side cover

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota R630 and is the answer not in the manual?

Kubota R630 Specifications

General IconGeneral
Engine Power64.4 HP
TransmissionHydrostatic
Travel Speed12.4 mph
Hydraulic Pump Flow17.4 GPM
Horsepower64.4 HP
Hydraulic System Flow17.4 GPM
Lift Height106.3 in (2, 700 mm)
Fuel Tank Capacity21.1 gal
Overall Width66.9 in (1, 700 mm)
Overall Height85.4 in (2, 170 mm)