63OPERATION OF THE MACHINE
HOW TO RELEASE PRESSURE TRAPPED
IN THE HYDRAULIC SYSTEM
1. Lower the attachments to the ground and activate the
hydraulic lock switch.
2. Turn the key to "STOP" position and shut off the
engine.
3. After stopping the engine, turn the key to "RUN"
position.
4. Deactivate the hydraulic lock switch.
5. Move the operating lever to release pressure in the
hydraulic system.
[How to release pressure trapped in the AUX port]
1. Perform the above operations of 1 to 4.
2. Turn "ON" the AUX port enable switch.
3. Make sure that the flow volume in all the AUX ports is
not minimized.
If the pressure is removed after minimizing the flow
volume in the AUX port, release pressure is not
removed completely and the hose coupler may be
unable to connect and disconnect.
[R630]
(1) Hydraulic lock switch (2) Hydraulic lock indicator
(1) AUX port enable switch (2) AUX operation indicator
(1) Display selector switch

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kubota R630 and is the answer not in the manual?

Kubota R630 Specifications

General IconGeneral
Engine Power64.4 HP
TransmissionHydrostatic
Travel Speed12.4 mph
Hydraulic Pump Flow17.4 GPM
Horsepower64.4 HP
Hydraulic System Flow17.4 GPM
Lift Height106.3 in (2, 700 mm)
Fuel Tank Capacity21.1 gal
Overall Width66.9 in (1, 700 mm)
Overall Height85.4 in (2, 170 mm)

Related product manuals