Configuration
Function blocks
Internal motor control with V/f characteristic control (MCTRL1)
8
8.2
8.2.6
8.2-30
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0140
select direct 0
Search direction during flying
restart process
z Positive direction of rotation:
The motor rotates in CW
direction with view on the
motor shaft
z Negative direction of rotation:
The motor rotates in CCW
direction with view on the
motor shaft
8.2-25
8.2-48
0 NSET Only search in the direction of the
applied setpoint
1 inv. Nset Only search against the direction
of the applied setpoint
2 pos. Only search in positive direction of
rotation
3 neg. Only search in negative direction
of rotation
4 Both, Nset Search at first in the direction of
the applied setpoint and then
against the direction
5 Both,inv.Nset Search at first against the
direction and then in the direction
of the applied setpoint
6 Both pos. Search at first in positive then in
negative direction of rotation
7 Both neg. Search at first in negative then in
positive direction of rotation
C0142 Start options 1
Starting condition for the flying
restart circuit
8.2-25
8.2-48
0 Start lock z Automatic start is inhibited
after
– mains connection
– Cancel of a message
(t > 0.5 s)
– Trip reset
z Flying restart circuit is inactive
z Start after HIGH-LOW-HIGH
level change at X5/28
1 Auto start Automatic start when
X5/28 = HIGH
z Flying restart circuit is inactive
2 flying lock z Automatic start is inhibited
after
– mains connection
– Cancel of a message
(t > 0.5 s)
– Trip reset
z Flying restart circuit is active
z Start after HIGH-LOW-HIGH
level change at X5/28
3 Fly restart Automatic start when
X5/28 = HIGH
z Flying restart circuit is active