Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8
8.2
8.2.7
8.2-50
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0021 Slipcomp Æ -20.00 {0.01 %} 20.00 Slip compensation
Æ Change of C0086, C0087 or
C0089 sets C0021 to the
calculated rated slip of the
motor
z When changing over to the
vector control mode, C0021 is
set to 0
6.11-1
8.2-25
8.2-48
C0022 IMAX CURRENT Æ 0 {0.01 A} - I
max
limit in motor mode
Æ Depending on C0086
6.6-12
C0023 Imax gen. Æ 0 {0.01 A} - I
max
limit in generator mode
Æ Depending on C0086
6.6-12
C0025
Feedback type 1
Speed feedback
6.7-1
1 no feedback No feedback
100 IT (C420) - X8 Input of the
number of
increments in
C0420
Incremental encoder at X8
z Incremental encoders with TTL
level can only be connected to
X8.
101 IT (C420) - X9 Input of the
number of
increments in
C0420
Incremental encoder at X9
z Connect incremental encoders
with HTL-level on X9 only
Number of
increments:
Incremental encoder at X8
z Incremental encoders with TTL
level can only be connected to
X8.
110 IT512-5V 512 inc
111 IT1024-5V 1024 inc
112 IT2048-5V 2048 inc
113 IT4096-5V 4096 inc
C0036 DC brk value 0.0 0.0 {0.1 A} - Set DC braking current
Æ depends on the controller
8.2-25
8.2-48
C0042 DIS: QSP
Quick stop
z Display only
8.2-25
8.2-48
0 QSP inactive Quick stop is not active
1 QSP active Quick stop is active
C0050 MCTRL-NSET2 -100.00 {0.01 %} 100.00 Speed setpoint, function block
MCTRL
z Display of the speed in [%] of
C0011
8.2-25
8.2-48
C0051 MCTRL-NACT -36000 {1 rpm} 36000 Actual speed value, function block
MCTRL
z Display only
8.2-25
8.2-48
C0052 MCTRL-UMOT 0 {1 V} 800 Motor voltage, function block
MCTRL
z Display only
z MCTRL-VACT = 100 % = C0090
8.2-25
8.2-48
C0053 Ug-voltage 0 {1 V} 900 DC-bus voltage, function block
MCTRL
z Display only
z MCTRL-DCVOLT = 100 % =
1000 V
8.2-25
8.2-48
C0054 IMot 0.0 {0.1 A} 500.0 Current motor current, function
block MCTRL
z Read only
z MCTRL-IACT = 100 % = C0022
8.2-25
8.2-48