Configuration
Code table
8
8.3
8.3-27
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0443 DIS: DIGIN-OUT
0 {1} 255 Terminal signals, function block
DIGIN
z Read only
z Binary interpretation of the
terminal signals at X5
See System
Manual
(extension)
Bit Assignment
0 DIGIN1 X5/E1
1 DIGIN2 X5/E2
2 DIGIN3 X5/E3
3 DIGIN4 X5/E4
4 DIGIN5 X5/E5
5 ST-DIGIN6 X5/ST
6 DIGIN-CINH X5/28
C0444
0
1
LOW signal
HIGH signal
Terminal signals, function block
DIGOUT
z Read only
See System
Manual
(extension)
DIS: DIGOUT1 Bit Assignment X5/A1
DIS: DIGOUT2 0 DIGIN1 X5/A2
DIS: DIGOUT3 1 DIGIN2 X5/A3
DIS: DIGOUT4 2 DIGIN3 X5/A4
C0450
CFG: NX 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block BRK1
z Speed threshold, from which
the drive may output the
signal ”Close brake”
See System
Manual
(extension)
C0451
CFG: SET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block BRK1
z HIGH = close brake
z LOW = open brake
C0452
CFG: SIGN 1000 FIXED0% Selection list 1 Configuration of analog input
signal, function block BRK1
z Direction of torque with which
the drive is to create a t orque
against the brake
C0458 -199.99 {0.01 %} 199.99
Function block BRK1
z Display of the signals linked in
C0450 and C0452
See System
Manual
(extension)
1 DIS: NX
2 DIS: SIGN
C0459 DIS: ON Function block BRK 1
z Display of the signal linked in
C0451
C0464 CUSTOMER I/F
0 original
Customer interface indicates the
status of the selected basic
configuration
z Reassignment of terminals in a
basic configuration does not
change C0005 and sets C0464
=1
z Adding or removing function
blocks or changing the signal
flow among the function
blocks in a basic configuration
setsC0005=0andC0464= 1
1 changed