Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8
8.2
8.2.7
8.2-75
EDSVF9333V EN 3.0-06/2005
Vector control
Use C0021 to change the influence of the rotor resistance (C0082)
proportionally:
ƒ Reduce the value in C0021 at an increasing speed (negative values)
ƒ Increase the value in C0021 at a decreasing speed
Note!
When setting the vector control mode, the slip compensation
(C0021) is automatically set to 0.0 %.
ƒ When you switch back to the V/f characteristic control mode,
the slip compensation must be re-adapted.
If the motor may only rotate in one direction, you can limit the output
voltage generation to one direction of rotation via C0909.
Code Description
C0909 = 1 The motor rotates in both directions
C0909 = 2 Motor rotates clockwise, ”positive direction of rotation
(View of the motor shaft)
C0909 = 3 Motor rotates counter-clockwise, ”negative direction of rotation”
(View of the motor shaft)
Slip compensation
Inhibiting the direction o f
rotation

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Lenze EVF9325 and is the answer not in the manual?

Lenze EVF9325 Specifications

General IconGeneral
Output Current25 A
Protection ClassIP20
Output Power11 kW
Control ModeSensorless vector control
Input Voltage380-480V AC
Control Methodvector control
Communication InterfacesRS485, CANopen
Output Voltage0-480V AC
Power11.0 kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit