Configuration
Code table
8
8.3
8.3-68
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C1354
CFG: REF 1000 FIXED0INC Selection list 3 Input signal configuration
z Reference value
See System
Manual
(extension)
C1355
CFG: IN 1000 FIXEDPHI-0 Selection list 4 Configuration of input signal,
function block INT1
z Angle of rotation
C1356
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block INT1
z HIGH = Sets the integrator to 0
C1357 DIS: REF -2000000000 {1 inc} 2000000000 Function block INT1
z Display of the signal linked in
C13554
See System
Manual
(extension)
C1358 DIS: IN -32767 {1 rpm} 32767 Function block INT1
z Display of the signal linked in
C1355
C1359 DIS: RESET 0 1 Function block INT1
z Display of the signal linked in
C1356
C1360 INT2 function 0
Function selection, function block
INT2
See System
Manual
(extension)
0 PHI >= REF If INT2-IN ≥ INT2-REF, INT2-DOUT
is set to HIGH
1 |PHI| >= |REF| If |INT2-IN| ≥ |INT2-REF|,
INT2-DOUT is set to HIGH
C1361 INT2 scaling 65536
00
65536 {1} 1000000000
Scaling factor, function block
INT2
INT2 − AOUT [%] =
INT2 − IN [inc]
C1361
⋅ 100 %
C1364
CFG: REF 1000 FIXED0INC Selection list 3 Input signal con figuration
z Reference value
See System
Manual
(extension)
C1365
CFG: IN 1000 FIXEDPHI-0 Selection list 4 Configuration of input signal,
function block INT2
z Angle of rotation
C1366
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block INT2
z HIGH = Sets the integrator to 0
C1367 DIS: REF -2000000000 {1 inc} 2000000000 Function block INT2
z Display of the signal linked in
C13564
See System
Manual
(extension)
C1368 DIS: IN -32767 {1 rpm} 32767 Function block INT2
z Display of the signal linked in
C1365
C1369 DIS: RESET 0 1 Function block INT2
z Display of the signal linked in
C1366
C1370 FOLL max 100.00 0.00 {0.01 %} 199.99 Upper limit, function block FOLL1
z Upper limit of the ramp
function generator
See System
Manual
(extension)
C1371 FOLL min -100.0
0
-199.99 {0.01 %} 0.00 Lower limit, function block FOLL1
z Lower limit of the ramp
function generator
C1372 FOLL Tir 10.0 0.1 {0.1 s} 6000.0
Acceleration time T
ir
and
deceleration time T
if
of the ramp
function generator, function
block FOLL1
C1373 FOLL Tif 10.0 0.1 {0.1 s} 6000.0