Configuration
Code table
8
8.3
8.3-14
EDSVF9333V EN 3.0-06/2005
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0142 Start options 1
Starting condition for the flying
restart circuit
8.2-25
8.2-48
0 Start lock z Automatic start is inhibited
after
– mains connection
– Cancel of a message
(t > 0.5 s)
– Trip reset
z Flying restart circuit is inactive
z Start after HIGH-LOW-HIGH
level change at X5/28
1 Auto start Automatic start when
X5/28 = HIGH
z Flying restart circuit is inactive
2 flying lock z Automatic start is inhibited
after
– mains connection
– Cancel of a message
(t > 0.5 s)
– Trip reset
z Flying restart circuit is active
z Start after HIGH-LOW-HIGH
level change at X5/28
3 Fly restart Automatic start when
X5/28 = HIGH
z Flying restart circuit is active
C0143 limit 2 kHz 0.0 0.0 {0.1 Hz} 20.0 Speed-dependent switching
threshold
z Threshold for automatic
switching frequency reduction
z The controller changes
automatically to 2 kHz when
this value falls below t he
threshold
8.2-25
8.2-48
C0144
OH switch 1
0 Switch off Switch-over is not
active
Temperature-dependent
switching frequency reduction
z If the heatsink temperature set
in C0122 is reached (warning
OH4), the controller switches to
2kHz
1 Switch on Switch-over is
active
C0145
select ref 1
Selection of the flying restart
mode
z Reference speed with which
the flying restart process is
started
8.2-25
8.2-48
0 REF: C0011 Maximum speed
1 REF: N-ACT Last current speed
2 REF: N-SET Defined main speed setpoint
It is referenced to the setpoint
signal at input NSET-N of the
function block NSET.
If the setpoint signal at input
NSET-N is missing, it is referenced
to the active JOG setpoint
(C0039/x)