EasyManuals Logo
Home>Manitowoc>Construction Equipment>14000

Manitowoc 14000 Service And Maintenance Manual

Manitowoc 14000
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
Reference Only
Manitowoc Published 09-10-14, Control # 065-24 3-1
14000 SERVICE MANUAL ELECTRIC SYSTEM
3
SECTION 3
ELECTRIC SYSTEM
ELECTRICAL DRAWINGS AND
SCHEMATICS
Electrical schematics are located at the end of this section.
CHECKING AND REPLACING ELECTRICAL
COMPONENTS
1. Visually inspect all electrical harnesses and cables
every month or at 200 hours of service life for the
following:
a. Damaged, cut or deteriorated harness loom
covering
b. Damaged, cut or abraded individual wires or cable
insulation
c. Exposed bare copper conductors
d. Kinked, crushed, flattened harnesses or cables
e. Blistered, soft, degraded wires and cables
f. Cracked, damaged, or badly corroded battery
terminal connections
g. Inspect all machine ground connections for
damaged terminals or excessive corrosion
h. Other signs of significant deterioration
If any of these conditions exist, evaluate the harness for
repair or replacement.
2. At the same service interval, visually inspect all
Controller Area Network (CAN) nodes and electrical
junction boxes for the following:
a. Damaged or loose connectors
b. Damaged or missing electrical clamps or tie straps
c. Excessive corrosion or dirt on the junction boxes
d. Loose junction box mounting hardware
If any of these conditions exist, address them
appropriately.
See Table 3-1
below for the following items.
3. Harness and battery cables operating in Zone C are
recommended to be replaced after 10,000 hours of
service life.
4. Harness and cables operating in Zone A and B with
high ambient temperatures and high duty circuits could
see electrical service life reduced by 25% to 40%. It is
recommended to replace these assemblies after 8,000
hours of service life.
5. Harness and cable assemblies operating in Zone D
and E, should expect a degrade of mechanical
properties and long term exposure to these cold
temperatures will negatively impact service life. It is
recommended for these electrical harnesses and cable
assemblies to be inspected to step 1 above as service
life may be more than 10,000 hours.
6. Harness and cable assemblies operating in salt water
climates could see a significant reduction in service life.
Therefore it is recommended for these electrical
harnesses and cable assemblies to be inspected to
step 1 above as service life may be more than 8,000
hours.
Table 3-1 Climate Zone Classification:
DANGER
Electrical Shock Hazard!
Ensure that the battery cables are disconnected from the
batteries before loosening any electrical connections.
Item Description
A Tropical Moist: All months average above 18° C.
Latitude: 15° - 25° N & S
B Dry or Arid: Deficient precipitation most of the year.
Latitude: 20° - 35° N & S
C Moist Mid-Latitude: Temperate with mild winters.
Latitude: 30° - 50° N & S
D Moist Mid-Latitude: Cold winters.
Latitude 50° - 70° N & S
E Polar: Extremely cold winters and summers.
Latitude: 60° - 75° N & S

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals