ELECTRIC SYSTEM 14000 SERVICE MANUAL
3-18
Published 09-10-14, Control # 065-24
Boom Remote Input Node
See Electrical Schematic A17144, Sheet 12 (at the end of this section).
Receptacle/
RIN ID
Wire No. Description Test Voltage
J1 Receptacle – Input/Output
301A P1A System Power 12 Volts Nominal
301B P1B Data Out Variable 0 to 12 Volts
301C P1C System Ground Ground
J2 Receptacle – Input/Output to Wind Speed RIN
302A P5A System Power 12 Volts Nominal
302B P5B Data In Variable 0 to 12 Volts
302C P5C System Ground Ground
J3 Receptacle – Boom Items
303G P6WT Block-Up Limit 1 - Lower 0 Volts Off; 12 Volts On
303E P6BK Block-Up Limit 1 - Lower CAN84-2-128
303N P9WT Block-Up Limit 2 - Upper 0 Volts Off; 12 Volts On
303H P9BK Block-Up Limit 2 - Upper CAN84-2-64
303P P3WT Block-Up Limit 3 - Fixed 0 Volts Off; 12 Volts On
303L P3BK Block-Up Limit 3 - Fixed CAN84-4-128
303B P4WT Maximum Jib Angle Limit 10 Volts Off; 12 Volts On
303A P4GN Maximum Jib Angle Limit CAN84-4-64
303C P5C Maximum Jib Angle Limit Ground
303B P4WT Minimum Jib Angle Limit 10 Volts Off; 12 Volts On
303K P2BK Minimum Jib Angle Limit CAN84-4-32
303C P5C Minimum Jib Angle Limit Ground
303J P7BN Load Sensor 1 2 to 20 Micro Amps
303D P7WT Load Sensor 1 AC 2
303F P7BK Load Sensor 1 Ground
303R P8BN Load Sensor 2 2 to 20 Micro Amps
303M P8WT Load Sensor 2 AC 1
303S P8BK Load Sensor 2 Ground
P Receptacle – Angle Sensor
P10 P10 Boom Angle Sensor Ground
P11 P11 Boom Angle Sensor AR 1
P12 P12 Boom Angle Sensor 5 Volts Nominal