Manitowoc Published 09-10-14, Control # 065-24 5-7
14000 SERVICE MANUAL HOISTS
5
MINIMUM BAIL LIMIT ADJUSTMENT
See Figure 5-5 for the following instructions.
NOTE: Reference to LED is past production only.
The optional minimum bail limit assembly on Drum 1 and 2
(front and rear) is a protective device which limits how much
wire rope can be spooled off each drum.
The minimum bail limit automatically stops the
corresponding drum when there are 3 to 4 wraps of wire rope
remaining on the first layer (View A).
The drum can be operated in the hoist direction when the
minimum bail limit switch is contacted.
Adjusting the minimum bail limit switch requires operating
the drum to spool wire rope off the drum.
Weekly Maintenance
1. Check minimum bail limit switch for proper operation.
a. LED (7, light emitting diode) in limit switch (6) should
be ON for normal operation.
b. Pay out wire rope from drum (4). Drum should stop
with approximately 3 to 4 wraps of wire rope
remaining on first layer — LED (7) should switch
OFF. Adjust limit switch (6) if necessary.
2. Check that cap screws (3) holding rollers (2) on lever
shaft are tight.
3. Check that return spring (11) has sufficient tension to
hold rollers (2) snugly against bare drum. Adjust
eyebolts (12) if necessary.
Limit Switch Head Position
When installing a new limit switch, reposition the head as
follows (View C):
1. Remove four screws attaching head to body.
2. Rotate head (90° increments) so lever (8) is positioned
as shown.
3. Install and securely tighten screws to attach head to
body.
Adjustment
1. Land load for drum being adjusted.
2. Loosen setscrew (9, View C) in limit switch lever (8) so
lever is free to rotate.
3. Pay out wire rope until bail limit rollers (2) are against
bare drum with 3 to 4 full wraps of wire rope remaining
on drum.
4. Hold roller on limit switch lever (8) against actuating
plate (5, View B).
5. Turn limit switch shaft (10) CLOCKWISE (when viewing
shaft) only enough to click limit switch open and hold.
LED will switch off.
6. Securely tighten setscrew (9) to lock adjustment.
7. Spool six to seven wraps of wire rope onto load drum.
8. Pay out wire rope from load drum. Drum must stop when
there are three to four wraps of wire rope remaining on
drum.
9. If necessary, repeat adjustment.
WARNING
Falling Load Hazard!
Do not operate drum with less than 3 or 4 full wraps of
wire rope remaining on drum. Doing so can cause wire
rope to be pulled out of drum and load to fall.

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals