14000 SERVICE MANUAL ELECTRIC SYSTEM
3
Node 1 — Master (Front Console)
See Electrical Schematic A17144, Sheets 5 and 15 (at the end of this section).
Connector
Number
Function
Type
Description Test Voltages
CAN Packet
Number
J1
Receptacle Front Console – (Not Used Terminals are Omitted)
P11-1 24 Volts
Input Power 24 Volts Nominal
P11-3 DI-12
Display Scroll Up Switch 0 Volts Off; 24 Volts On CAN92-4-8
P11-4 DI-14
Display Scroll Down Switch 0 Volts Off; 24 Volts On CAN92-4-32
P11-5 DI-31
Display Exit Switch 0 Volts Off; 24 Volts On CAN92-6-64
P11-6 DI-9
Display Enter Switch 0 Volts Off; 24 Volts On CAN92-4-1
P11-8 DO-3
RCL Warning L.E.D. 0 Volts Off; 24 Volts On CAN92-1-4
P11-10 DO-6
RCL Caution L.E.D. 0 Volts Off; 24 Volts On CAN92-1-32
P11-11 24 Volts
Power to Membrane (Display) Switches 24 Volts Nominal
P11-13 DI-11
Limit Bypass Switch 0 Volts Off; 24 Volts On CAN92-4-4
P11-14 DI-13
Jib Up Limit Bypass Switch 0 Volts Off; 24 Volts On CAN92-4-16
P11-15 DI-32
Load/Luffing Jib (Drum 3) Park Switch 0 Volts Off; 24 Volts On CAN92-6-128
P11-16 DI-10
Confirm Switch 0 Volts Off; 24 Volts On CAN92-4-2
P11-21 Ground
Ground to Node 2 and Displays 1 & 2 Ground
P11-24 DI-30
Swing Park Switch 0 Volts Off; 24 Volts On CAN92-6-32
P11-29 Ground
RCL Caution L.E.D. Ground
P11-30 Ground
RCL Warning L.E.D. Ground
P11-31 CANH
CAN High Data Line from Node 2 N/A
P11-32 CANL
CAN Low Data Line from Node 2 N/A
P11-33 DI-27
Display 1 0 Volts Off; 24 Volts On CAN92-6-4
P11-34 DI-29
Display 2 0 Volts Off; 24 Volts On CAN92-6-16
J2 Receptacle – Front Console (Not Used Terminals are Omitted)
P12-1 24 Volts
Input Power 24 Volts Nominal
P12-7 DO-9
Jib Bypass/Swing Park Switch 24 Volts Nominal CAN92-2-1
P12-8 DO-11
Drums 1, 2, and 3 Park Switches 24 Volts Nominal CAN92-2-4
P12-9 DO-16
Drum 4/Travel Park Switches 24 Volts Nominal CAN92-2-128
P12-11 24 Volts
Gauge Panel 24 Volts Nominal
P12-13 DI-3
Front Drum (Drum 1) Park Switch 0 Volts Off; 24 Volts On CAN92-3-4
P12-14 DI-5
Rear Drum (Drum 2) Park Switch 0 Volts Off; 24 Volts On CAN92-3-16
P12-15 DI-24
Boom Hoist (Drum 4) Park Switch 0 Volts Off; 24 Volts On CAN92-5-128
P12-17 DO-10
Overhead Panel 24 Volts Nominal CAN92-2-2
P12-21 Ground
Ground to Node 2 and Displays 1 & 2 Ground
P12-24 DI-22
Engine Run/Start 0 Volts Off; 24 Volts On CAN92-5-32
P12-25 DI-7
Travel Park Switch 0 Volts Off; 24 Volts On CAN92-3-64
P12-26 DI-17
Boom Hinge Pins Disengage 0 Volts Off; 24 Volts On CAN92-5-1
P12-31 CANH
CAN High Data Line to Graphical Display N/A
P12-32 CANL
CAN Low Data Line to Graphical Display N/A
P12-33 DI-19
DPF Inhibit 0 Volts Off; 24 Volts On CAN92-5-4
P12-34 DI-21
DPF Regen Initiate 0 Volts Off; 24 Volts On CAN92-5-16

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals