7. Install Filters by Hand:
Insert new safety filter (1e) carefully and push into back
of housing. Apply pressure to all four corners of filter to
make sure filter is secure in housing (1f).
Repeat this step for primary filter (1d).
8. Install Service Cover:
Once filter is in place, put service cover (1b) back on,
making sure evacuator valve (1a) points in direction
shown. Fasten latches (1c). Cover should go on without
extra force. Push reset button on service indicator to
reset
Never use latches on cover to force filters into air
cleaner! It is tempting to assume cover will do the job of
sealing the filter – but it will not! Using latches to push
filters in could damage housing and will void warranty.

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications