2202MYJE-MY-C8-N_2018.02.
Chapter 2 Compressor Specifications and Structure
Compound 2-stage Screw Compressor 3225**C 2.3 Compressor Specifications
2-4
2.3.2 Operation Limits
Table 2-3 Operation Limits of 3225**C
Maximum discharge pressure
Maximum intermediate pressure
Minimum intermediate pressure
・ Maximum journal lubrication pressure
Discharge pressure + 0.39
・ Minimum journal lubrication pressure
Discharge pressure +0.049 and
Suction pressure +0.49
・ Minimum oil injection lubrication pressure
Maximum Suction temperature
Minimum suction temperature
Maximum low-stage discharge temperature
Maximum high-stage discharge temperature
Maximum oil supply temperature
Minimum oil supply temperature
Maximum male rotor rotation speed
Minimum male rotor rotation speed
Note : Unless otherwise noted, the pressure unit MPa represents the gauge pressure in this manual.
If operation at partial load, which is not greater than 30 % of the indicated load, is
continued for a long time except when starting up the machine, abnormal noises
or vibration may be generated. So avoid such operation.
Repeated startup and stop in a short period is harmful not for the startup devices
and electric machinery but also for the compressor itself. For information on the
start/stop limitations, refer to each instruction manual. Wait at least 15 minutes
after stopping the compressor before restarting it.