4 NIBE F1330
User guide
A B I II
A B
13.43
1.0
P
50.0°C
Varmvattentemperatur
Front panel
A B
A B
I II
Front panel
Display
Right keypad
Left keypad
Heating
curve offset
Compressor symbol
Indicates that one of the compressors in the heat
pump is operational.
A indicates that compressor A (lower module) is
operational.
B indicates that compressor B (top module) is
operational.
Additional symbol
Indicates when immersion heater is operational.
Extra hot water symbol
Indicates when the Extra hot water function is active.
A indicates that a temporary temperature increase
is activated.
B indicates that a time determined temperature
increase, for example periodic, is activated.
Circulation pump symbol
I indicates that the heating medium pump A is
operational.
II indicates that the heating medium pump B is
operational.
Oil boiler symbol
Indicates that the oil boiler is activated.
Switch
The program ignores the enter button being pressed
when key lock is activated, this prevents the settings
from being changed unintentionally. Key lock is ac-
tivated in the main menus by pressing the plus and
minus buttons simultaneously. The key symbol will
then be shown on the display. The same procedure
is used to deactivate the key lock.
The symbol becomes visible when a timer function is
selected, for example, periodic lowering of the flow-
temperature or time setting for extra hot water.
Screen saver mode
In screen saver mode, you can
see any alarms as well as the flow
temperatures currently given by
the compressors (VBFA and VBFB)
and whether the heat pump is a
Master or Slave. The screen saver
is deactivated by pressing the
enter button and the button in
the lower left for approximately 8
seconds. Menu 1.0 is then dis-
played. The screen saver comes
on automatically 30 minutes after
the last button was pressed and
when starting the heat pump.
Display
First row:
Second row: Value of the current parameter.
Third row: Description of current display parameter.
Fourth row: Shows menu numbers, key lock, clock
symbol and time.
54,1 55,7 °C
Slave 3
HP-ALARM
Slave 3