5. Horizontal Distance Input after Angle-only Shot
Press the [O/S] key on the BMS and select [5] to
enter the Input HD function.
3
O/S: 5. Input H
D
Turn the telescope to the direction of the point you
are to store and input the HD (usually taped distance
from the instrument point).
HD
Tgt
Input PT (and CD) and press the [ENT] key.
The target point (Tgt) is calculated and recorded to
the Job as a SS record.
= Sample records in [O/S]
[5.Input HD] =
SS,158,0.0000,77.0518,62.08380,108.06510,11:51:48,
CO, Input HD:76.1243
This function is convenient when the instrument is very close to the point and is
difficult to take a measurement using the EDM.