5-3. Upload PT-List/Code-List File
Press the [3] key to upload a Point List and [4] for
the Code List file via cable.
3
MENU: 5. Comm
Connect the RS-232C cable and start a terminal
program on your PC.
Press [OK] or [ENT] to put the instrument into
“Receiving a List file” mode.
• When you upload a Code List, it always replaces the existing one on the instrument.
As the List is uploaded, the counter is updated as
each line in the List is stored.
Maximum 254 codes (or point names for PT List)
can be stored.
• The system will truncate the code if it is longer than 16 characters.
3-127