EasyManuals Logo
Home>Omron>Controller>R88D-1SN30F-ECT

Omron R88D-1SN30F-ECT User Manual

Omron R88D-1SN30F-ECT
974 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #614 background imageLoading...
Page #614 background image
9 Details on Servo Parameters
9 - 54
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
Sets the torque limit function.
Selects the torque limit switching method.
When 1 or 2 is set, positive and negative torque limit values vary with state of the torque limit input
(PCL/NCL) and Controlword (P_CL/N_CL).
When the maximum torque value is smaller than the other torque limit values, it is used as the limit
value.
Description of Set Values
Sets the maximum torque limit value. The function of this object is the same as the Max torque
(6072 hex). Set this object when you use a limit value without mapping 6072 hex to a PDO.
9-5-7 3330 hex: Torque Limit
Index
(hex)
Sub-
index
(hex)
Object name
Setting
range
Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes of
opera-
tion
3330 --- Torque Limit --- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Switching Selec-
tion
0 to 2 --- 0 A 4 bytes
(INT32)
RW --- --- cst
02 Max Torque 0 to 5,000 0.1% 5,000 A 2 bytes
(U16)
RW - - csp, csv,
cst, pp,
pv, hm
03 Positive Torque
Limit Value
0 to 5,000 0.1% 5,000 A 2 bytes
(U16)
RW --- --- csp, csv,
cst, pp,
pv, hm
04 Negative Torque
Limit Value
0 to 5,000 0.1% 5,000 A 2 bytes
(U16)
RW --- --- csp, csv,
cst, pp,
pv, hm
05 Positive Torque
Limit Value 2
0 to 5,000 0.1% 5,000 A 2 bytes
(U16)
RW --- --- csp, csv,
cst, pp,
pv, hm
06 Negative torque
limit value 2
0 to 5,000 0.1% 5,000 A 2 bytes
(U16)
RW - - csp, csv,
cst, pp,
pv, hm
81 Status --- --- --- --- 4 bytes
(INT32)
RO --- --- csp, csv,
cst, pp,
pv, hm
Subindex 01 hex: Switching Selection
Set value Description
0 Switching by PCL/NCL signal is not allowed. Use the Positive torque limit value and Negative
torque limit value.
1 Use the Positive Torque Limit Value 2 when both of the torque limit input (PCL) and Control-
word (P_CL) are OFF, and the Positive Torque Limit Value for the other combinations.
If both the torque limit input (NCL) and Controlword (N_CL) are OFF, the Negative torque limit
value 2 is used. In other cases, the Negative torque limit value is used.
2 Use the Positive Torque Limit Value when both of the torque limit input (PCL) and Controlword
(P_CL) are OFF, and the Positive Torque Limit Value 2 for the other combinations.
If both the torque limit input (NCL) and Controlword (N_CL) are OFF, the Negative torque limit
value is used. In other cases, the Negative torque limit value 2 is used.
Subindex 02 hex: Max Torque

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN30F-ECT and is the answer not in the manual?

Omron R88D-1SN30F-ECT Specifications

General IconGeneral
BrandOmron
ModelR88D-1SN30F-ECT
CategoryController
LanguageEnglish

Related product manuals