14 – Command Reference
Show Alarm
59263-01 A 14-135
A
Show Alarm
Displays the alarm log and session output stream display setting.
Authority None
Syntax show alarm
settings
Keywords settings
Displays the status of the parameter that controls the display of alarms in the
session output stream. This parameter is set using the Set Alarm command.
Notes The alarm log is cleared when the switch is reset or power cycled.
Examples The following is an example of the Show Alarm command:
SANbox #> show alarm
[1][Fri Jan 19 13:50:26.508 UTC 2007][A][1004.000F][Port: 4][Eport Isolating
due to Merge Zone Failure]
[2][Fri Jan 19 13:50:26.513 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 1]
[3][Sun Jan 21 07:59:28.677 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 99]
[4][Sun Jan 21 07:59:29.367 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 101]
The following is an example of the Show Alarm Settings command:
SANbox #> show alarm settings
Current settings for alarm
--------------------------
display ON

Table of Contents

Other manuals for Qlogic SANbox 5802V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5802V and is the answer not in the manual?

Qlogic SANbox 5802V Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5802V
CategorySwitch
LanguageEnglish

Related product manuals