2 Command System RIGOL
DS2000E Programming Guide
2-253
:TRIGger:CAN:LEVel
Syntax
:TRIGger:CAN:LEVel <level>
:TRIGger:CAN:LEVel?
Description
Set or query the trigger level of CAN trigger when the trigger source is CHANnel1 or CHANnel2. The unit
is the same with the current amplitude unit.
Parameter
Name Type Range Default
<level> Real (-5 x VerticalScale - OFFSet) to (+5 x VerticalScale - OFFSet)
0
Note: For the VerticalScale, refer to the :CHANnel<n>:SCALe command. For the OFFSet, refer to
the
:CHANnel<n>:OFFSet command.
Explanation
To set the CAN trigger source, please refer to the
:TRIGger:CAN:SOURce command.
Return Format
The query returns the trigger level of CAN trigger when the trigger source is CHANnel1 or CHANnel2 in
scientific notation.