TROUBLESHOOTING
15
99
• Incasefusereplacementsotherthanthosestatedinthismanualare
necessary,contactwhereyoupurchasedtheproductfromforinquiriesregarding
thismatter.
• In order to prevent an electric shock, be sure to turn power off and unplug
fromthesocketoutletbeforeperformingworkbytouchingtheinternalpartsofthe
product.
• Be careful so asnot to damage wirings.Damaged wiring can causeelectric
shockandshortcircuitaccidents.
• Besureto usefusesmeetingspecifiedrating.Using fusesexceedingthe
speciedratingcancausereandelectricshockaccidents.
• Aftereliminatingthecauseoftheblowingoffuse,replacethefuse.Depending
onthecauseoffuseblowing,continuedusewiththefuseasisblowncancause
generationofheatandrehazard.
Replacing Fuses
Fuses are located on the following:
RD-1540UK Assy AC Unit (1) 5A Time Delay 20mm
(1) 5A Time Delay 20mm (Spare)
838-14551-02UK AC Distribution PCB (2) 6.3A Time Delay 20mm
FR-838-0001UK Servo Driver PCB (1) 3A Time Delay 36mm
390-4018-FR-UK FL Tray 110-240v 2x18w (1) 3A 26mm