Connecting
6.5 Power supply
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
133
Connecting 24 V safety extra-low voltage (SELV)
The power supply is connected using a 4-pin plug-in terminal block.
The power supply can be connected redundantly. Both inputs are isolated. There is no
distribution of load. When a redundant power supply is used, the power supply unit with
the higher output voltage supplies the IE Switch X-300 alone.
The power supply is connected over a high resistance with the enclosure to allow an
ungrounded set up. The two power inputs are non-floating.
Terminal block assignment (4-pin)
Table 6- 1 Pinout of the 24 V safety extra-low voltage (SELV)
Pin number
Assignment
Labeling (example)
Pin 1
L1+ 24 V DC
Pin 2
M1
Pin 3
M2
Pin 4
L2+ 24 V DC
6.5.1.2
24 VDC - product group X-300
Table 6- 2 24 to 48 VDC safety extra-low voltage overview
Device
Device version
(power supply)
24 V safety extra-low voltage
(SELV)
can be connected redundantly
X304-2FE
1 x 24 VDC
X306-1LD FE
1 x 24 VDC
X307-3
1 x 24 VDC
X307-3LD
1 x 24 VDC
X308-2
1 x 24 VDC
X308-2LD
1 x 24 VDC
X308-2LH
1 x 24 VDC
X308-2LH+
1 x 24 VDC
X310
1 x 24 VDC
X310FE
1 x 24 VDC

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals