Technical specifications
8.5 Technical specifications for X-300EEC
SCALANCE X-300
182 Operating Instructions, 05/2016, A5E01113043-20
8.5.4
Other properties
Table 8- 63 Switching properties
Max. number of learnable addresses
8000
Aging time
30 sec
Switching technique
Store and forward
Latency
5 μs
Table 8- 64 Reconfiguration times for redundancy mechanisms
Redundancy mechanism
Reconfiguration times
HRP
300 ms
Standby link
300 ms
MRP
200 ms
Table 8- 65 Mean time between failure (MTBF)
Device variant
Device version
MTBF
1)
X302-7EEC
1 x power supply unit 24 VDC
27 years
2 x power supply unit 24 VDC
19 years
1 x power supply unit 100 to 240 VAC /
60 to 250 VDC
22 years
2 x power supply unit 100 to 240 VAC /
60 to 250 VDC
15 years
X307-2EEC
1 x power supply unit 24 VDC
29 years
2 x 24 VDC power supply unit
20 years
1 x power supply unit 100 to 240 VAC /
60 to 250 VDC
24 years
2 x power supply unit 100 to 240 VAC /
60 to 250 VDC
16 years
1)
These values apply at 40 °C.
Note
The IE Switches X
-300 support "full wire speed switching" complying with IEEE 802.3 on all
ports. The number of packets therefore depends on the packet length.

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals