EasyManuals Logo
Home>Siemens>Switch>SCALANCE X308-2

Siemens SCALANCE X308-2 User Manual

Siemens SCALANCE X308-2
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
Technical specifications
8.2 X-300 technical specifications
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
163
8.2.4
Other properties
Table 8- 14 Switching properties
Max. number of learnable addresses
8000
Aging time
30 sec
Switching technique
Store and forward
Latency
5 μs
Table 8- 15 Reconfiguration times for redundancy mechanisms
Redundancy mechanism
Reconfiguration times
HRP
300 ms
Standby link
300 ms
MRP
200 ms
Table 8- 16 Mean time between failure (MTBF)
Device variant
MTBF
1)
X304-2FE
55 years
X306-1LD FE
65 years
X307-3
40 years
X308-2
42 years
X307-3LD ,
X308-2LD,
X308-2LH,
X308-2LH+,
38 years
X310,
X310FE
45 years
X320-1 FE
35 years
X320-3LD FE
30 years
1)
These values apply at 40 °C.
Note
The IE Switches X
-300 support "full wire speed switching" complying with IEEE 802.3 on all
ports. The number of packets therefore depends on the
packet length.

Table of Contents

Other manuals for Siemens SCALANCE X308-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X308-2 and is the answer not in the manual?

Siemens SCALANCE X308-2 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X308-2
CategorySwitch
LanguageEnglish

Related product manuals