Technical specifications
8.6 XR-300M EEC technical specifications
SCALANCE X-300
190 Operating Instructions, 05/2016, A5E01113043-20
Table 8- 80 Switching properties
Max. number of learnable addresses
Table 8- 81 Reconfiguration times for redundancy mechanisms
Mean time between failure (MTBF)
The values in the following table apply to the basic device without media modules.
Device version (power supply)
1 x 24 to 48 VDC
or
1 x 100 to 240 VAC / 60 to 250 VDC
> 15 years
2 x 24 to 48 VDC
or
2 x 100 to 240 VAC / 60 to 250 VDC
> 15 years
2)
These values apply at 40 °C.
The redundant power supply unit increases the reliability of the system. The MTBF value of the
power supply unit is > 20 years.
In the calculation of the MTBF of a modular switch, the standard parts count applies; in other
words, the reciprocals of all component failure rates are added.
The reciprocal of this total id the MTBF of the entire assembly.
Table 8- 82 Full wire speed switching
Number of frames per second