Approvals, certificates, standards
9.4 X-300EEC product group
SCALANCE X-300
248 Operating Instructions, 05/2016, A5E01113043-20
Overview of the approvals for the X-300EEC
Table 9- 4 Overview of the approvals
c-UL-us
for Hazard-
ous Loca-
tions
1)
24 to 48
● ● - ● ● ● ●
100...240
VAC /
60...250
- - ● - ● ● -
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
X-300EEC mechanical stability (in operation)
All variants of the IE Switch SCALANCE X-300EEC meet the following requirements for
mechanical stability:
● IEC 60068-2-6 (vibration)
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
● IEC 60068-2-27 (shock)
15 g, 11 ms duration
6 shocks per axis
For further details, refer to the technical specifications.