8.5.2.5 Intervals - Step 4/7
In this step, you can dene the intervals for measurements and data transfers. The remaining
battery life is recalculated based on your entry.
Note
Calculated battery life
The calculated battery life is a statistical value. The actual remaining battery life may dier
depending on temperature inuences or the connection quality of the Wi-Fi network.
Note
Eects that inuence the battery life
Shorter intervals result in a shorter battery life.
The following intervals are preset in the factory:
• 5 minutes - interval for measuring temperature, vibrations, rotational frequency, operating
status
You can change these settings within a specied range.
• 10 minutes - interval to calculate speed, torque and energy consumption
This interval cannot be set, it is dependent on the selected measurement interval. The
calculation interval is three times as long, i.e. 3 minutes, for a
measurement interval of 1 minute. The calculation interval is twice as long for
measurement intervals 2 and 5 minutes. The calculation interval is the same length for all
other measurement intervals.
• 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet"
You can modify these settings within a preset range of 1 to 48 hours.
Note
To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes.
Maintenance
8.5Replacing the connectivity module
SIMOTICS CONNECT 400
146 Operating Instructions, 04/2023, A5E50161952B AL