2-2. Method of Coping with Shift Lens Error
2-2-1. E:62:02 Abnormality of IC for Steadyshot
Identify the cause of the problem (lens or VC-1045 board), and replace the faulty lens or the VC-1045 board.
2-2-2. E:62:11 Shift Lens Overheating (Pitch)
Start the Adjust Manual in the Adjust Station and execute the “Measure to E:62:11/12” on the SERVICE tab.
Then confirm that the shift lens moves. If it does not move, replace the lens block.
Identify the cause of the problem (lens or VC-1045 board), and replace the faulty lens or the VC-1045 board.
2-2-3. E:62:12 Shift Lens Overheating (Yaw)
Start the Adjust Manual in the Adjust Station and execute the “Measure to E:62:11/12” on the SERVICE tab.
Then confirm that the shift lens moves. If it does not move, replace the lens block.
Identify the cause of the problem (lens or VC-1045 board), and replace the faulty lens or the VC-1045 board.
2-2-4. E:62:20 Abnormality of Thermistor
Check the connection between the lens block and VC-1045 board.
Identify the cause of the problem (lens or VC-1045 board), and replace the faulty lens or the VC-1045 board.
HXR-NX80/HXR-MC88
2-5