18. Electrical System
18-4
Battery
Removal
Remove the battery cover (2 nuts).
Disconnect the negative pole first and then the
positive pole.
Remove the battery.
Voltage inspection
Use the digital voltmeter to check the voltage
of the battery.
Full charged:12.8V ↑(20°C)
Undercharged:12.0 V↓ (20°C)
Warning
y Keep flames away while recharging.
y Charging is completely controlled by
the ON/OFF switch on the charger, not
by battery cables.
Charging
Connect the positive terminal (+) of the
charger to the battery positive terminal.
Connect the negative terminal (-) of the
charger to the battery negative terminal.
Standard Maximum
Charging current 0.9A 4A
Charging time 5~10 hours 1 hour
Caution
y Never rapid charge the battery unless in
emergency.
y Verify the battery is recharged with current
and duration prescribed above.
y Large current and fast time to charge will
render damage to the battery.
After installing the battery, coat the cable
terminal with grease.
2 nuts
To this chapter contents