SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

10V24 control and V25ter
Page 106 of 307
10.17î™–î™–î™–î™–Command dial modifier time S8
S8
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
10.17.1î™–î™–î™–î™–Description
Specifies the amount of time, in seconds, that the DCE shall pause during dialling, when a ',' (comma) dial
modifier is encountered in a dial string.
The command has no effect.
10.17.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set ATS8=<value> OK ATS8=4
OK
Read ATS8? <value>
OK
002
OK
10.17.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number Range 0 - 255. The answer to the read command is in "xxx" format. The default value
is 2.
10.18î™–î™–î™–î™–Automatic disconnect delay S10
S10
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
10.18.1î™–î™–î™–î™–Description
Specifies the time in tenth of a second, that the DCE will remain connected to the line after the DCE has
indicated the absence of received line signal. Not supported for GSM but the OK response is returned.
10.18.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set ATS10=<value> OK ATS10=30
OK
Read ATS10? <value>
OK
030
OK
10.18.3î™–î™–î™–î™–Defined values
Parameter Type Description
<value> Number Range 1 - 254. Default: 1
10.18.4î™–î™–î™–î™–Notes
SARA-R4 / SARA-N4
• The command has no effect.