SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

5Mobile equipment control and status
Page 28 of 307
5î™–î™–î™–î™–Mobile equipment control and status
5.1î™–î™–î™–î™–Module switch off +CPWROFF
+CPWROFF
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No < 40 s +CME Error
5.1.1î™–î™–î™–î™–Description
Switches off the MT. During shut-down current settings are saved in module's non-volatile memory.
Using this command can result in the following command line being ignored.
See the corresponding System Integration Manual for the timing and the electrical details of the module
power-off sequence via the +CPWROFF command.
5.1.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Action AT+CPWROFF OK
Test AT+CPWROFF=? OK
5.2î™–î™–î™–î™–Set module functionality +CFUN
+CFUN
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No Up to 3 min +CME Error
5.2.1î™–î™–î™–î™–Description
Selects the level of functionality <fun> in the MT.
SARA-R4 / SARA-N4
If the syntax +CFUN=15 or +CFUN=16 (resets) or +CFUN=127 is used, the rest of the command line, placed
after that will be ignored.
SARA-R4 / SARA-N4
A SW reset via AT+CFUN=1,1 triggers signalling attempts whose number is internally counted by the SW
and limited based on mobile network operators' thresholds. The AT&T RPM feature (see also the +URPM
AT command) limits the number of SW resets per hour, and might cause the AT command to return an
error result code.
5.2.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set AT+CFUN=<fun>[,<rst>] OK AT+CFUN=1
OK
Read AT+CFUN? +CFUN: <power_mode>,<STK_
mode>
OK
+CFUN: 1,0
OK
Test AT+CFUN=? +CFUN: (list of supported <fun>'s),
(list of supported <rst>'s)
OK
+CFUN: (0,1,4,6,7,8,15,16),(0-1)
OK