SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

5Mobile equipment control and status
Page 32 of 307
5.4.3î™–î™–î™–î™–Defined values
Parameter Type Description
<conf> Number The unsigned integer (0 to 4095) is a bitmask representing the list of the indications
active for +CIEV URC reporting. The bit position corresponds to the indicator order
number (see the <descr> parameter of +CMER). The least significant bit is used for
the first indicator.
The bits corresponding to unused indicator order numbers (greater than 13) must be
set to 0 (setting a <conf> greater than 4095 causes an error). The default value is 40
95 (all the indications are enabled).
5.5î™–î™–î™–î™–Mobile termination event reporting +CMER
+CMER
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
5.5.1î™–î™–î™–î™–Description
Configures sending of URCs from MT to DTE for indications. The <mode> parameter controls the processing
of URCs specified within this command.
The URC is generated each time an indicator which is defined in +CIND command changes status. The code is
actually submitted to MT according to the +CMER settings.
The command +UCIND allows enabling or disabling indicators.
5.5.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set AT+CMER=[<mode>[,<keyp>[,
<disp>[,<ind>[,<bfr>]]]]]
OK AT+CMER=1,0,0,2,1
OK
Read AT+CMER? +CMER: <mode>,<keyp>,<disp>,
<ind>,<bfr>
OK
+CMER: 1,0,0,0,1
OK
Test AT+CMER=? +CMER: (list of supported
<mode>'s),(list of supported
<keyp>'s),(list of supported
<disp>'s),(list of supported <ind>'s),
(list of supported <bfr>'s)
OK
+CMER: (0-3),(0),(0),(0-2),(0,1)
OK
URC +CIEV: <descr>,<value>
5.5.3î™–î™–î™–î™–Defined values
Parameter Type Description
<mode> Number
• 0 (default value): buffer URCs in the MT
• 1: discard URCs when the V.24 interface is reserved for data; otherwise directly
display them on the DTE
• 2: buffer URCs in MT when the V.24 interface is reserved and flush them after
reservation; otherwise directly display them on the DTE
• 3: same as 1
<keyp> Number
• 0: no keypad event reporting
<disp> Number
• 0: no display event reporting
<ind> Number
• 0: no indicator event reporting
• 1: indicator event reporting using the +CIEV URC. Only the indicator events which
are not caused by +CIND shall be indicated by the MT to the DTE.
• 2: indicator event reporting using the +CIEV URC. All the indicator events shall be
directed from MT to DTE.

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals