SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R09

5Mobile equipment control and status
Page 30 of 307
5.3î™–î™–î™–î™–Indicator control +CIND
+CIND
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No No No - +CME Error
5.3.1î™–î™–î™–î™–Description
Provides indication states related to network status, battery information and so on.
The set command does not allow setting the values for those indications which are set according to module
state (see <descr> parameter).
The list of indications for set and read commands follows the indexes reported in the <descr> parameter, so
that the first <ind> corresponds to "battchg" and so on.
For more details see the 3GPP TS 27.007 [2].
5.3.2î™–î™–î™–î™–Syntax
Type Syntax Response Example
Set AT+CIND=[<ind>[,<ind>[,...]]] OK AT+CIND=
OK
Read AT+CIND? +CIND: <ind>[,<ind>[,...]]
OK
+CIND: 5,0,0,0,0,0,0,0,0,0,0,0
OK
Test AT+CIND=? +CIND: (list of <descr>s)
OK
+CIND: ("battchg",(0-5)),("signal",
(0-5)),("service",(0,1)),("sounder",
(0,1)),("message",(0,1)),("call",(0,1)),
("roam",(0,1)),("smsfull",(0,1)),("gprs",
(0-2)),("callsetup",(0-3)),("callheld",(0
,1)),("simind",(0-2))
OK
5.3.3î™–î™–î™–î™–Defined values
Parameter Type Description
<ind> Number Range of corresponding <descr> used to identify the service when an unsolicited
indication is provided
<descr> String Reserved by the norm and their <ind> ranges; it may have the values:
• "battchg": battery charge level (0-5)
• "signal": signal quality. See mapping in the note below
• "service": network service availability
o 0: not registered to any network
o 1: registered to the network
o 65535: indication not available
• "sounder": sounder activity, indicating when the module is generating a sound
o 0: no sound
o 1: sound is generated
• "message": unread message available in <mem1> storage
o 0: no messages
o 1: unread message available
• "call": call in progress
o 0: no call in progress
o 1: call in progress
• "roam": registration on a roaming network
o 0: not in roaming or not registered
o 1: roaming
o 65535: indication not available

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals