Type Syntax Response Example
Test AT+UCUSATA=? +UCUSATA: (list of supported
<active_URC>s)
OK
+UCUSATA: (0-3)
OK
URC +CUSATP: <proactive_command>
URC +CUSATEND
12.5.3î™–î™–î™–î™–Defined values
Parameter Type Description
<active_URC> Number URC enabling/disabling. Allowed values:
• 0 (default value): disables all USAT URCs
• 1: enables the +CUSATEND URC
• 2: enables the +CUSATP URC
• 3: enables both USAT URCs
<proactive_
command>
String Command in hexadecimal character format. Proactive command as defined in 3GPP
TS 31.111 [119], consisting of the full BER-TLV data object.
12.5.4î™–î™–î™–î™–Notes
• The MT uses the unsolicited result code +CUSATP: <proactive_command> to forward to the TE proactive
commands issued by the UICC.
• The unsolicited result code +CUSATEND is issued by the MT when the UICC indicates that the proactive
command session is terminated.
• Terminal responses to the proactive commands can now be issued with +CUSATT and envelope
commands can be issued with +CUSATE

Table of Contents

Other manuals for Ublox SARA-R4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ublox SARA-R4 Series and is the answer not in the manual?

Ublox SARA-R4 Series Specifications

General IconGeneral
BrandUblox
ModelSARA-R4 Series
CategoryControl Unit
LanguageEnglish

Related product manuals